Integrated Mobile Phase Preparation System_Galatek

Integrated Mobile Phase Preparation System
Integrated Mobile Phase Preparation System
Automated systems that enable LC and LC-MS analytical workflows
·

Solutions

Integrated Mobile Phase Preparation System

Integrated Mobile Phase Preparation System
Integrated Mobile Phase Preparation System

This fully integrated system automates preparation of mobile phases used in HPLC and LC-MS workflows. User permissions and traceability ensure data generation, storage, and review meet FDA 21 CFR Part 11 standards.

• Supports standardized mobile phase preparation to reduce variability and reruns
• Built for reliable, repeatable performance in routine and regulated workflows
• Integrates easily into existing high-throughput analytical lab environments

Features

Whole Process Automation
Whole Process Automation
Realize the automation of the whole process of mobile phase preparation, and the seamless connection from raw material input to finished product output
Select by Throughput
Select by Throughput
The mobile phase preparation throughput can be selected within the range of 50-200 L/day based on the actual requirements, and functional modules can be selected as needed
Simple and Easy to Use
Simple and Easy to Use
Support the formulation design, and has the automatic alarm function for low inventory of reagents and consumables to improve operation convenience and use efficiency
Fully Meet Compliance Requirements
Fully Meet Compliance Requirements
Systematically and strictly comply with GMP and FDA 21 CFR Part 11 requirements to ensure the compliance of the production process and the product quality

Product Parameter


Product ModelAutomated Mobile Phase Preparation Workstation
Product configurationFunctional modeSolid feeding
Liquid feeding
pH adjustment
Stirring formBlade
Filtration and dispensing
Ultrasonic degassing
Labeling/ Tagging
Preparation rate100 L/day
Additional functionsAutomatic calibration procedure for pH meter
Automatic calibration procedure for balance
Product parametersEquipment dimension4 m * 2 m * 2.1 m
Stock of reagent raw materials12 types
Stock of powder raw materials9 types
Mobile phase preparation range1 L/2 L/5 L
Powder dispensing accuracy≤ 1% (based on loading amount)
Reagent dispensing accuracy≤ 1%
pH adjustment range0-14
pH measurement accuracy0.01 pH
Weighing accuracy1/10,000
ComplianceGMP/FDA21 CFR Part 11
Power supply220 V/50 Hz; 8 kW